Abstract

AbstractSince that pathogenic bacteria are major threats to human health; this research describes the fabrication of an effective and sensitive platform based on graphene oxide/poly deep eutectic solvent/nickel oxide nano particles (GO/PDES/NiO NPs) nanocomposite at the surface of glassy carbon electrode for selective detection of Staphylococcus aureus (S. aureus). The DNA aptamers were immobilized on the modified electrode through the EDC/NHS chemistry. Each aptasensor modification step was checked by with cyclic voltammetry (CV) and electrochemical impedance spectra (EIS) techniques. The linear dynamic range of the proposed electrochemical aptasensor covered a large variation of S. aureus concentrations from 101 – 108 CFU.mL−1 and a detection limit of 10 CFU.mL−1 under optimum conditions was obtained. Analysis of spiked tap water, lake water and human serum samples revealed high potential of this aptasensor as a sensitive, effective, and label‐free promising tool for S. aureus detection. This is the first time that poly deep eutectic solvents used in live bacteria detection.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call