Abstract

Determination of isoproterenol (ISP) was carried out using a DNA incorporated poly(1-methylpyrrole) modified glassy carbon electrode (GCE). The poly(1-methylpyrrole)-DNA/GCE showed an excellent electrocatalytic effect on the oxidation of ISP. The poly(1-methypyrrole)-DNA/GCE also accelerated the rate of electron transfer reaction of ISP. Compared with a bare GCE, the poly(1-methylpyrrole)-DNA/GCE exhibits a distinct shift of the oxidation potential of ISP in the cathodic direction and a marked enhancement of the current response. A linear calibration plot was obtained covering the concentration range from 2.0 × 10-6 to 6.0 × 10-5 M with a detection limit of 1.60 × 10-7 M by cyclic voltammetry. The electrode system has also successfully resolved the overlapping anodic peak of ISP and uric acid (UA) into two well-defined voltammetric peaks in cyclic voltammetry at 0.416 V and 0.552 V for ISP and UA, respectively. The poly(1-methypyrrole)-DNA/GCE has successfully been utilised for the determination of ISP in pharmaceutical preparations. The validity of the proposed method was also assured by the recovery of ISP and UA in urine samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.