Abstract

BackgroundThe micro waveform of His bundle potential can’t be recorded beat-to-beat on surface electrocardiogram yet. We have found that the micro-wavelets before QRS complex may be related to atrioventricular conduction system potentials. This study is to explore the possibility of His bundle potential can be noninvasively recorded on surface electrocardiogram.MethodsWe randomized 65 patients undergoing radiofrequency catheter ablation of paroxysmal superventricular tachycardia (exclude overt Wolff-Parkinson-White syndrome) to receive “conventional electrocardiogram” and “new electrocardiogram” before the procedure. His bundle electrogram was collected during the procedure. Comparative analysis of PAs (PA interval recorded on surface electrocardiogram), AHs (AH interval recorded on surface electrocardiogram) and HVs (HV interval recorded on surface electrocardiogram) interval recorded on surface “new electrocardiogram” and PA, AH, HV interval recorded on His bundle electrogram was investigated.ResultsThere was no difference (P > 0.05) between groups in HVs interval (49.63 ± 6.19 ms) and HV interval (49.35 ± 6.49 ms). Results of correlational analysis found that HVS interval was significantly positively associated with HV interval (r = 0.929; P < 0.01).ConclusionsHis bundle potentials can be noninvasively recorded on surface electrocardiogram. Noninvasive His bundle potential tracing might represent a new method for locating the site of atrioventricular block and identifying the origin of a wide QRS complex.

Highlights

  • The micro waveform of His bundle potential can’t be recorded beat-to-beat on surface electrocardiogram yet

  • Wang et al BMC Cardiovascular Disorders (2017) 17:82 recorded on surface electrocardiogram) interval, AHs (AH interval recorded on surface electrocardiogram) interval and HVs (HV interval recorded on surface electrocardiogram) interval

  • Comparative analysis of PA interval recorded on surface electrocardiogram (PAs), AHs and HVs interval recorded on surface “new electrocardiogram” and PA, AH, HV interval recorded on His bundle electrogram was investigated in 65 patients undergoing radiofrequency catheter ablation of paroxysmal superventricular tachycardia

Read more

Summary

Introduction

The micro waveform of His bundle potential can’t be recorded beat-to-beat on surface electrocardiogram yet. We have found that the micro-wavelets before QRS complex may be related to atrioventricular conduction system potentials. This study is to explore the possibility of His bundle potential can be noninvasively recorded on surface electrocardiogram. It is difficult to evaluate the sinoatrial function, locate the site of atrioventricular block and identify the origin of a wide QRS complex on surface. Comparative analysis of PAs, AHs and HVs interval recorded on surface “new electrocardiogram” and PA, AH, HV interval recorded on His bundle electrogram was investigated in 65 patients undergoing radiofrequency catheter ablation of paroxysmal superventricular tachycardia.

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.