Abstract

The electrocaloric effect was observed in association with an electric-field induced metal-insulator transition in VO2 using a calorimetric measurement under an applied voltage. For a VO2 plate with a 0.4 mm thickness located in the center of a capacitor-like structure, the metal-insulator transition was manipulated by applying a few volts. The occurrence of a transition in such a thick sample with relatively low voltage indicates that a surface charge accumulation mechanism is effective. The isothermal entropy change reached 94 J kg−1 K−1, while the adiabatic temperature change was calculated as −3.8 K under a voltage change of 0–3 V. The large entropy change is attributed to correlation of the complex freedom among spin, charge, and lattice.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.