Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background Electric conduction disturbances are very common, however, patients in need for ventricular pacing may suffer from pacing-induced heart failure due to unphysiological pacing by the right ventricular lead. Conducting system pacing allows to overcome this common issue with a more physiologic approach, but real-life procedural data using this technology is scarce. Methods We report a single centre experience of the first 63 consecutive patients being implanted with a His-bundle-based pacemaker 09/2020-11/2022 per 3D-mapping guided implantation due to bradyarrhythmia, or for cardiac resynchronisation therapy in heart failure combined with a left-ventricular lead (HOT-CRT) ± a right ventricular defibrillator lead. The identification of the His-bundle-location was done with a 3D electroanatomic mapping system via an introducing sheath that is provided with electrodes at its tip. Results Mean age was 71 [18;87] years, 18/63 (29%) patients were female, mean baseline LVEF was 46±15%. Baseline ECG was captured before implantation: QRS width was 127±34ms, with typical LBBB in 19/63 (30%), typical RBBB in 5/63 (8%), alternating BBB in two patient (3%) and either no BBB or ventricular escape rhythm in 37/63 (59%). Indications for implantation were AV-block grade II-III in 31/63 (49%), primary prophylactic ICD indication in HFrEF in 18/63 (29%), atrial fibrillation with bradycardic conduction in 8/63 patients (13%), sick-sinus-syndrome in 4/63 (7%) and secondary prophylactic ICD indication in one patient (2%). In 57/63 (90,5%) a primary device was implanted, in 6/63 (9,5%) a pre-existent device was upgraded with a HB lead. Therefore, 23 dual-chamber-pacemaker, 5 single-chamber-pacemaker, 10 single-chamber CRT-P, 17 dual-chamber CRT-P, 4 single-chamber CRT-D, 4 dual-chamber CRT-D were implanted. In 63 patients his bundle pacing was attempted, while in 6/63 (9%) patients outside of this analysis the attempt was not successful, these patients were consecutively implanted with a non-HBP-device and therefor excluded from the further analysis. In the 63 patients included in this analysis with a primary successful pacing at the his-position, 5/63 (8%) his-bundle-leads dislocated within the first 48 hours, leading to a secondary success rate of 92%. There were two post-procedural pneumothorax that needed drainage, no major procedure-related complications occurred. Median skin-to skin procedure time was 111±47 minutes in his-bundle-device-implantation. The paced QRS width at the post-implantation follow up was 113±27ms with a change in QRS width of -15±39ms (+72; -92ms). The mean his-bundle sensing was 5,38±5,6mV and the mean threshold 1,1±0,86V over 1,0±0,5ms (0,4;1,5ms). The proportion of ventricular pacing was 75±36%. Conclusion Electroanatomic-guided His bundle pacing as a new innovative technic for physiological pacing is viable including high implantation success rate as well as electric impact, both regarding QRS width and pacing threshold.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.