Abstract

AbstractThe design of efficient electrochemical setups to precisely and timely quantify the oxygen permeability, which dictates how the lens let O2 to reach the eye, is important for the development lens‐based materials. We report herein a home‐made electro‐analytical platform made of a 3D‐printed diffusion electrochemical cell to assess this parameter. The design overcomes edge effects and allows analysis under conditions similar to lens wear where the liquid is in contact to the inner surface while the gaseous O2 is in contact with the outer surface. The testing of three types of contact lens materials (flexible polymer, rigid polymer, and gel‐type) showed that the O2 permeability can be fairly well evaluated by the chronoamperometry study of oxygen reduction reaction. Under conditions similar to those of lens wear, our findings showed that the measurement error was 6 %, which offer an alternative to the classic gas‐to‐gas method for O2 permeability determination.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.