Abstract

AbstractGold nanoparticles (Au‐NPs), cystamine (CA) and 3,3′‐dithiodipropionic acid (DTDPA) modified gold bare electrodes were applied in voltammetric sensors for simultaneous detection of norepinephrine (NEP), ascorbic (AA) and uric (UA) acids. A linear relationship between norepinephrine concentration and current response was obtained in the range of 0.1 μM to 600 μM M with the detection limit ≤0.091 μM for the electrodes modified at 2D template and in the range of 0.1 μM to 700 μM M with the detection limit ≤0.087 μM for the electrodes modified at 3D template The results have shown that using modified electrodes it is possible to perform electrochemical analysis of norepinephrine without interference of ascorbic and uric acids, whose presence is the major limitation in norepinephrine determination at a bare gold electrode. The modified SAMs electrodes show good selectivity, sensitivity, reproducibility and high stability.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call