Results from an experimental study of field-assisted crossflow microfiltration are presented. It was found that both electric and ultrasonic fields, either in isolation or in combination, can reduce membrane fouling by an amount dependent on the applied field strengths, acoustic frequency, suspension concentration, liquid viscosity, particle size and particle surface charge. Synergistic effects were observed when the fields were applied simultaneously. When force fields are used in microfiltration lower crossflow velocities can be employed. This implies that pumping costs, heat transfer in recirculation loops and the degradation of shear sensitive streams can be substantially reduced.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.