Abstract

Electric-field-controlled magnetic responses are investigated in Metglas and lead zirconate titanate based laminated composites by using induction method within different frequencies. The largest value of converse magnetoelectric (CME) coefficient is 4.18G/V at the resonance frequency of 103kHz under a low magnetic bias field of 45Oe. Furthermore, the CME coefficient and optimum magnetic bias field can be tuned in a wide range by applying dc electric field biases. The CME characteristics with the frequency of driving electric voltage, magnetic bias field, and different dc electric field biases are discussed in present paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.