Abstract

Electrically controlled drug delivery of neurochemicals and biomolecules from conducting polymer microelectrode coatings hold great potentials in dissecting neural circuit or treating neurological disorders with high spatial and temporal resolution. The direct doping of a drug into a conducting polymer often results in low loading capacity, and the type of molecule that can be released is limited. Poly(3,4-ethylenedioxythiophene) (PEDOT) doped with sulfonated silica nanoparticles (SNP) has been developed as a more versatile platform for drug delivery. In this work, we demonstrate that neurochemicals with different surface charge, e.g., glutamate (GLU), gamma-Aminobutyric acid (GABA), dopamine (DA), 6,7-Dinitroquinoxaline- 2,3-dione (DNQX) and bicuculline, can be, respectively, incorporated into the SNP and electrically triggered to release repeatedly. The drug loaded SNPs were incorporated in PEDOT via electrochemical deposition on platinum microelectrodes. After PEDOT/SNP(drug) coating, the charge storage capacity (CSC) increased 10-fold to 55 ± 3 mC/cm2, and the impedance at 1 kHz was also reduced approximately 6-fold. With the aid of a porous SNP, the loading capacity and number of releases of GLU was increased >4-fold and 66-fold, respectively, in comparison to the direct doping of PEDOT with GLU (PEDOT/GLU). The focal release of GLU and GABA from a PEDOT/SNP (drug) coated microelectrode were tested in cultured neurons using Ca imaging. The change in fluo-4 fluorescence intensity after electrically triggered GLU (+6.7 ± 2.9%) or GABA (−6.8 ± 1.6%) release indicated the successful modulation of neural activities by neurotransmitter release. In addition to activating neural activities, glutamate can also act on endothelial cells to stimulate nitric oxide (NO) release. A dual functional device with two adjacent sensing and releasing electrodes was constructed and we tested this mechanism in endothelial cell cultures. In endothelial cells, approximately 7.6 ± 0.6 nM NO was detected in the vicinity of the NO sensor within 6.2 ± 0.5 s of GLU release. The rise time of NO signal, T0–100, was 14.5 ± 2.2 s. In summary, our work has demonstrated (1) a platform that is capable of loading and releasing drugs with different charges; (2) proof of concept demonstrations of how focal release of drugs can be used as a pharmacological manipulation to study neural circuitry or NO’s effect on endothelial cells.

Highlights

  • Miniaturized microelectrodes are favorable in neuroscience due to the reduced invasiveness, increased spatial resolution and selectivity

  • After an initial charging surge, a gradual decrease in electrode potential is observed for all coatings, indicating a continuous decrease in electrode impedance as the PEDOT/silica nanoparticles (SNP) coating grows, a typical characteristic of the conducting polymer

  • This study demonstrated robust nitric oxide (NO) generation when GLU was released to endothelial cells from PEDOT/SNP

Read more

Summary

Introduction

Miniaturized microelectrodes are favorable in neuroscience due to the reduced invasiveness, increased spatial resolution and selectivity. Microelectrodes can be used to study neurochemical interplay and neural circuitry dynamics when coupled to drug delivery tools. Neurochemical signals have been extensively reported when excitative or inhibitive drugs were injected to region of interest [6,7,8]. These studies rely on pharmacological perturbation to localized cell populations. Microcapillary tubes or microfluidic injection tools are often employed in such studies. These methods require additional hardware and are subject to drug leakage or system integration complexity

Methods
Results
Conclusion
Full Text