Electrical tree growth in epoxy resin under square waves superimposed with DC voltages is studied in this paper. Using the needle-plane configuration, a ±15 kV DC voltage superimposed on a 15 kV pk 50 Hz square wave was applied to grow electrical trees. A standard 50 Hz sinusoidal source was also used for comparison. A CCD camera imaged the electrical tree growth during testing and associated partial discharges were recorded. It was observed that the tree shape under 15 kV square-wave voltages combined with positive or negative 15 kV DC voltages are branch-like, whereas bush-branch trees grow under 15 kV bipolar square-wave voltages. Positive unipolar square-wave voltages resulted in faster growth than negative unipolar square waves. The different tree structures were also associated with distinct characteristic PD activity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.