Abstract

This article proposes a high-level engineering guide to develop an integrated system model for power quality analysis in electrical submersible pump (ESP) applications with variable frequency drives (VFDs). Such analyses are troublesome in the industry due to the complexity of these systems. In this article, simple steps to perform system integration analyses of such arrangements, including torsional analysis, are developed. A simplified VFD-ESP model suitable for coupled electrical and mechanical analysis in steady state is proposed in all their configurations of practical interest. Such a model can be easily implemented in common simulation software, significantly reducing engineering efforts for implementation and analysis. The focus of the proposed model is the prediction of ESP failures that might result from a poor power quality caused by VFDs. Analytical expressions of different types of harmonics in these systems, as well as their accurate locations in the frequency domain, including their interharmonics and common-mode harmonics, are derived for this purpose. The effectiveness of the proposed model is verified through offline and real-time hybrid simulation results. Finally, a comparison between simulation results obtained using the proposed model and measurements collected on a down-scale laboratory prototype is carried out to demonstrate the accuracy of the suggested modeling approach.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call