Abstract

Abstract In order to study the reinforcement mechanism of the single fluid alkalization method and to consider the possibility of using the permeation variation of loess, direct shear tests of loess were performed before and after the strengthening process of single fluid alkalization, and the resistivity of loess was measured. The test results indicate that the shear strength of alkaline loess samples is significantly higher than those without alkaline, due to a series of physical and chemical reactions occurring after the injection of lye. With the increase of the electrical current frequency, the vertical and horizontal resistivities of loess decrease quickly at first and then become stable. When the electrical current frequency is below 50 kHz, even a slight change of the current frequency will greatly affect the measured resistivity values of loess. When the electrical current frequency is above 50 kHz, the resistivity of loess seems no longer be affected by the current frequency. The vertical resist...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.