Abstract
This paper presents two models: one for predicting the electrical resistivity of concrete and the other for the corrosion potential of reinforcing steel. The prediction models were developed based on experimental results, considering various influencing factors. The experiment approach included the concrete mix proportion, chloride content, concrete cover thickness and time of exposure as the parameters. The results revealed that fly ash concrete showed significantly high electrical resistivity even in the presence of chloride ions. The effects of fly ash became more significant when the water to binder ratio was lower. Chloride ions also decreased the corrosion potential of steel in both the OPC and fly ash concrete. The corrosion potential was found less negative for fly ash concrete due to higher electrical resistivity. The prediction results show good agreement with the experimental results of this study and some other researchers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.