Abstract

A 22.9 kV/50 MVA class high-temperature superconducting (HTS) power cable system was developed in Korea. For the optimization of electrical insulation design for HTS cable, it is necessary to investigate the ac and impulse breakdown and partial discharge inception stress of the liquid nitrogen (LN2)/ laminated polypropylene paper (LPP) composite insulation system. These results were used to insulation design of the model cable for a 22.9 kV class HTS power cable and the model cable was manufactured. The insulation test of the manufactured model cable was evaluated in various conditions and was satisfied standard technical specification in Korea. Based on these experimental data, the single-phase and three-phase HTS cable of a prototype were manufactured and verified.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.