Abstract

Electrical impedance tomography (EIT) is based on the physical principle of bioimpedance defined as the opposition that biological tissues exhibit to the flow of a rotating alternating electrical current. Consequently, here, we propose studying the characterization and classification of bioimpedance patterns based on EIT by measuring, on the forearm with eight electrodes in a non-invasive way, the potential drops resulting from the execution of six hand gestures. The starting point was the acquisition of bioimpedance patterns studied by means of principal component analysis (PCA), validated through the cross-validation technique, and classified using the k-nearest neighbor (kNN) classification algorithm. As a result, it is concluded that reduction and classification is feasible, with a sensitivity of 0.89 in the worst case, for each of the reduced bioimpedance patterns, leading to the following direct advantage: a reduction in the numbers of electrodes and electronics required. In this work, bioimpedance patterns were investigated for monitoring subjects’ mobility, where, generally, these solutions are based on a sensor system with moving parts that suffer from significant problems of wear, lack of adaptability to the patient, and lack of resolution. Whereas, the proposal implemented in this prototype, based on the so-called electrical impedance tomography, does not have these problems.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call