Abstract
Electrical resistance tomography (ERT) was used to image the full-scale test emplacement of a thin-wall grout barrier installed by high-pressure jetting and a thick-wall polymer barrier installed by low-pressure permeation injection. Both case studies compared images of electrical resistivity before and after barrier installation. Barrier materials were imaged as anomalies which were more electrically conducting than the native sandy soils at the test sites. Although the spatial resolution of the ERT was insufficient to resolve flaws smaller than a reconstruction voxel (50 cm on a side), the images did show the spatial extent of the barrier materials and therefore the general shape of the structures. To verify barrier performance, ERT was also used to monitor a flood test of a thin-wall grout barrier. Electrical resistivity changes were imaged as a saltwater tracer moved through the barrier at locations which were later found to be defects in a wall or the joining of two walls.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.