Abstract

The analysis of electrical erosion characteristics of contacts under DC load is conducive to the in-depth study of the arc erosion mechanism. Through the electrical contact experiment, the electrical erosion status of the Pt-Ir-Zr alloy under DC load of 25V/15A is studied in this paper. The results show that: the contacts have excellent anti-welding behavior and lower loss on arc ablation. The separation acceleration of the breaking process between the movable and static contacts is 154.32μm/ms2. The arc erosion surfaces of the material show a large number of paste-like coagulum and bubbles. There are some micro-cracks existing on the surface of the Pt-Ir-Zr alloy contacts. The obvious material transfer phenomenon occurs between the movable and static contacts under DC load.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.