Abstract
Abstract Silver and silver(Ag)-graphene(Gr) nanocomposite coatings were prepared via direct current, pulse current and pulse reverse current on copper electrical contacts for evaluating electrical contact performance. The effects of the addition of Gr and current types on microstructure, crystallographic orientation, mechanical properties and electrical contact performance were investigataed via a scanning electron microscope, an X-Ray diffractometer, microhardness test device and an electrical contact test device, respectively. The addition of Gr changed the Ag surface morphology and decreased grain sizes. Moreover, the addition of Gr significantly improved arc erosion resistivity and decreased the average working temperature during the contact test. In addition, pulse current and pulse reverse current provided a significant improvement in microhardness and electrical contact erosion resistance owing to increased embedded graphene amounts in silver layers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.