Magnetotelluric (MT) surveys have revealed the existence of subvertical conductors at depths of several kilometers in the volcanic and geothermal areas of northern Japan. The conductive anomalies suggest that saline magmatic fluids are trapped within or in the vicinity of granitic intrusions and potentially form supercritical geothermal reservoirs. Detailed interpretation of the observed conductivity is a challenging task, as estimating the contributions of the pore fluids to the bulk conductivity of the systems requires specific information. Such information includes the in situ pressure, temperature, and salinity conditions in the conductors.In this study, we modeled magmatic fluids as H2O-NaCl fluids and developed a new approach to estimate the electrical conductivity of the fluids at elevated temperatures up to 525 °C and salinity up to 25 wt% NaCl. Using our developed approach, the possible ranges of fluid electrical conductivity were calculated under supercritical geothermal conditions. Further, we examined the pressure, temperature, and salinity conditions required to explain these observations.Our study showed that H2O-NaCl fluids in the vapor and halite coexistence states likely have extremely low conductivity that could not explain the observed conductors. This finding indicated that relatively shallow conductors located above 4 km could have abnormally high pressures if the phase relations of in situ fluids were close to those of the H2O-NaCl fluids. Salinity of more than 0.5 wt% NaCl is necessary for single-phase fluids to account for such observation. Whether the fluids in the liquid and vapor coexistence state could have such high conductivity is currently uncertain owing to a lack of experimental data. Further, our predictions about the depth variation of fluid conductivity indicated that near-lithostatic pressures, or extremely high temperatures (above 550 °C) under sufficiently high pressures are required to reproduce the observed nearly uniform distribution with depth. However, it is currently difficult to rule out the possibility that a shallower part of the conductors is cooled to approximately 400 °C, as MT inversion could have difficulty in accurately capturing a small variation in conductivity within the conductors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.