Abstract

In this study, the electrical resistivity of a glass-ceramic sealant is evaluated at 850 °C, for 2800 h under the applied voltage of 1.6 V. The glass-ceramic sealant is sandwiched between two Crofer22APU plates to produce Crofer22APU/Glass-ceramic/Crofer22APU samples. The Crofer22APU/glass-ceramic/Crofer22APU joints show electrical resistivity around 106-107 Ω cm, significantly high to ensure the insulation between two conductive interconnect plates. The detailed SEM-EDS post mortem analysis showed good thermo-mechanical compatibility of the glass-ceramic with the Crofer22APU substrates, thus excluding any detrimental interaction with the metallic interconnect under high applied voltage. XRD analysis of glass-ceramic confirmed the presence of crystalline phases with suitable CTEs, after electrical resistivity under harsh conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.