Abstract

Electrical capacitance volume tomography (ECVT) is a newly developed imaging technique that can quantify three-dimensional (3D) multiphase flows in a complex, geometric flow field. In this study, the 3D phase distribution images inside a gas–solid circulating fluidized bed (CFB) are obtained using ECVT. Specifically, measurements are made at a riser section and a 90° bend-shape riser exit section of the CFB. Inside the vertical riser, a symmetric core–annulus structure with a low solids holdup in the riser center along with a high solids holdup near the riser wall is observed. The average volume solids holdup and the thickness of the annulus decrease with the superficial gas velocity. A core–annulus flow structure is formed both in the vertical and horizontal parts of the bend. The annulus structure is noncentro-symmetric in the horizontal part of the bend. The solids holdup in the annulus near the top wall area in the bend is higher than that in other locations of the annulus. At a higher superficial gas...

Full Text
Published version (Free)