Abstract

The location of electrical breakdown in a composite insulating system has been measured. In these experiments, a paper sample was mounted so that it connected the two electrodes. Electrode structures ranging from plane-plane to sphere sphere were used. The electrode-paper system was tested in oil to determine the properties of an oil paper interface. The data indicated that, in a carefully prepared system, the breakdown will not necessarily occur at the interface. In addition, it was found that breakdown voltages were not significantly lower for those breakdowns which occurred at the interface than for those which did not. It was noted that if the paper was not dried or if many gaseous voids were left in or on the paper, the breakdown regularly occurred at the interface and at a lower voltage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.