Abstract

Low voltage cables play a crucial role in the safe and reliable operation of nuclear power plants. This paper discusses the effect of simultaneous combined thermal and mechanical stresses on the overall insulation of unshielded low voltage power cables used in nuclear power plants. Cable samples based on XLPE/CSPE insulation were exposed to thermal-mechanical combined accelerated aging tests for an extended period lasted to 907 hours. Time and frequency domain dielectric spectroscopy were applied to reveal the degradation level of the core insulation and jacket due to combined stresses. The former technique was conducted through the measurement of the decay and return voltage slopes, while the latter technique was based on the measurement of the complex permittivity. Moreover, the mechanical properties of the cable insulation were investigated by applying the measurement of the Shore D hardness. The results showed that the combined aging affects both the electrical and mechanical properties of the overall insulation. The complex permittivity at 100 Hz, the decay voltage slope, and the hardness had an upward trend with aging, while the return voltage slope showed an inverse trend. In addition, the results of the electrical and mechanical measurements showed strong correlation with aging time and further correlation was observed between the dielectric and mechanical properties. The correlation between aging time and test results suggests that the presented test methods are promising tools for in situ condition monitoring of low voltage unshielded cables in nuclear power plants.

Highlights

  • For the safety of the nuclear power industry, it is essential to successfully implement the quality assurance and quality control

  • Multi-factor aging of the polymeric insulation of nuclear power plant cables is a complex phenomenon, but the pursuit of a predictive understanding of the effects of combined simultaneous exposure to thermal and mechanical stresses on the insulation integrity of nuclear power plant cables is of utmost importance for the nuclear safety and management decisions

  • This research evaluated and confirmed the applicability of three potential non-destructive techniques for assessing the degradation of unshielded low voltage XLPE/chlorosulphonated polyethylene (CSPE) insulation-based power cables used in nuclear facilities

Read more

Summary

Introduction

For the safety of the nuclear power industry, it is essential to successfully implement the quality assurance and quality control. For ensuring the nuclear safety and longterm operation, all Nuclear Power Plant (NPP) elements. The associate editor coordinating the review of this manuscript and approving it for publication was Yu Wang. Have to be with a high degree of reliability and integrity, in particular, the nuclear reactors, concrete structure, heat exchangers, and cable systems [1]–[3]. In November 2020, there are 442 nuclear reactors in service all over the world with a total net electrical capacity of 392,335 MW and there are 53 more under construction which will increase the net capacity by 56,276 MW. A. Afia et al.: Electrical and Mechanical Condition Assessment of Low Voltage Unshielded Nuclear Power Cables

Objectives
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call