Abstract

The paper describes four different types of micro-electrodes systems for dynamic electric field sensing with photonic crystal fibers infiltrated with liquid crystals. The shortest switching time ∼20 ms was achieved by using a flexible-flat-cable electrode system. A capillary system with four micro-electrodes (τ ∼ 36 ms) appeared to be the most convenient to operate with photonic liquid crystal fibers. The capillary system was also theoretically analyzed and presented in this paper.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call