Abstract

Two silver wire brushes were held in contact with a rotating copper slip ring in an ultrahigh vacuum system. After initial sputter cleaning of the copper slip ring, the vacuum system was backfilled with humidified CO 2 to a pressure of 1 atm. A d.c. electric current was passed across the silver brushcopper slip ring-silver brush assembly and the resulting wear particles were analyzed using scanning electron microscopy and electron probe microanalysis. The slip ring surface was analyzed using Auger electron spectroscopy to determine the amount of silver transferred. Currents ranging from 0 to 50 A were used. In each case the numbers of pure copper, pure silver, copper-rich and silver-rich particles were recorded as a function of the current. The Auger signal from the slip ring and the concentrations of the elements in the wear debris were plotted versus the current to determine the role of current in the present Cu-Ag system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.