Abstract

Electret microphones with stiff plates instead of flexible diaphragms are described. The stiff plate and a backplate, separated by a soft cellular polymer spacer ring, yield a capacitance that is varied by the incoming sound wave; thus a voltage change in the plates is induced. Various such plate microphones were built and characterized. Sensitivities of more than 10 mV/Pa and equivalent noise levels of 23 dB(A) are obtained. An analytical model for the sensitivity of plate microphones was developed. Advantages of the plate microphones are high mechanical robustness, low harmonic distortion, and no risk of membrane collapse.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.