Abstract

In this study, a circulation-type fluidized bed boiler's exergy performance in a power generation plant was investigated. The boiler was examined not as a whole but by dividing it into its sub-systems. In the analysis, the sub-systems' exergy performance was evaluated in terms of criteria such as exergy efficiency, exergy destruction, fuel depletion ratio, relative exergy destruction ratio, exergetic improvement potential, and productivity lack ratio. In addition, the effect of different dead state temperatures on these exergy performance criteria is compared and discussed. As a result of the analysis, the highest exergy efficiency was achieved in the furnace with 80.2% at 6℃, while the highest exergy destruction occurred in the furnace as 18,118.9 kW at 27℃. The highest exergetic improvement potential was realized in Economizer-II with 11,593.82 kW at 6℃, and the lowest in Economizer-I at 27℃ with 631,9 kW. The effect of the increase in the dead state temperature on the exergy performance criteria applied to boiler sub-systems was variable. It showed its effect as an increase in some sub-systems and a decrease in others.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.