Abstract

A precision thermostat is described which has a relative RMS temperature constancy of ±.10 m°C over a week. Maximum temperature deviation from mean temperature during one week is typically ±.2m°C. The distribution of temperature along the middle axis of the thermostat is almost linearly increasing with height with a mean gradient of +.05 m°C/cm. We further investigated the stability of NTC resistances as temperature sensing elements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.