Abstract

An electrohydrodynamic (EHD) atomization from a point-to-plate system, with a wet porous point as a corona electrode, has been studied. And the atomized water droplets from the wet porous point, as well as the water droplet traces, the water droplet charge-to-mass ratios, and the water droplet number concentrations, were investigated. It was observed that the wet porous point can atomize abundant amounts of water droplet, 2.8, 2.6 and 2.2 mg/min for negative, AC and positive corona, respectively. The migrated water droplet traces were observed. The positive wet porous point atomized very fine water droplets than those obtained with the negative wet porous point. Moreover, the water droplets atomized from the AC corona showed granular-like larger traces. A weak corona discharge can atomize water droplets very effectively. On the other hand, an intensive corona discharge can eject more water droplets. As a result with the wet porous point, the maximum corona-current-based and corona-power-based water droplet atomization yield s of Y C = 3.34, 3.32 and 3.25 μg/μAs and Y P = 0.35, 0.40 and 0.27 mg/Ws have been obtained for the negative, AC and positive corona discharges.