Abstract

Abstract In recent years, TNS has attracted wide attention because of its simplicity in synthesis and high efficiency in ion exchange. The adsorption of cesium ions in aqueous solution by TNS was investigated in this study. Results show that the removal rate of Cs (I) is about 88% when pH = 5.00 ± 0.05, C0 = 10 ppm and CTNS = 0.1 g/L. The adsorption equilibrium is reached in about 20 minutes and best fits the pseudo-second order model, R2 = 0.9998; compared with the Freundlich isotherm adsorption model and Temkin model, the Langmuir model has the best fitting effect, R2 = 0.9903. The fitting results show the maximum adsorption capacity of TNS for Cs (I) is 200.00 mg/g. The main adsorption mechanism of TNS to cesium ion is ion exchange. Therefore, TNS can be used as a potential adsorbent for effectively adsorbing Cs-containing wastewater.