The use of pyroaurite type sorbents for removal of Cd(II) from aqueous solution has been studied. In batch tests, the sorbents IRA, PTS, PAC, PLC, FeO(OH) and RH could remove 95.3 ,93.8 , 93.9, 90.4, 75.1 and 59.5% cd (II) at initial metal concentration 0.1 mg/l, pH 6.0, temperature 25°C, agitation time 5 h, sorbent dose 5 g/l and rpm 150. The order of cadmium removal capacities for these chemical adsorbents was found to be: IRA > PTS > PAC > PLC >FeO(OH) > RH. The effects of various parameters affecting the adsorption such as initial metal concentration. Sorbent dose, contact time and pH were determined. Adsorption decreases with in cadmium concentration and pH but increases with increase in adsorbent dose and contact time. Equilibrium was attained in 5 h and the maximum removal was at pH 8. Thus, basic medium favoured the removal. The sorption data fitted very well to the Langmuir isotherm as well as the Freundlich equation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.