Abstract

Compressed Sensing (CS) theory breaks the Nyquist theorem through random under-sampling and enables us to reconstruct a signal from 10%-50% samples. Magnetic Resonance Imaging (MRI) is a good candidate for application of compressed sensing techniques due to i) implicit sparsity in MR images and ii) inherently slow data acquisition process. In multi-slice MRI, strong inter-slice correlation has been exploited for further scan time reduction through interpolated compressed sensing (iCS). In this paper, a novel fast interpolated compressed sensing (FiCS) technique is proposed based on 2D variable density under-sampling (VRDU) scheme. The 2D-VRDU scheme improves the result by sampling the high energy central part of the k-space slices. The novel interpolation technique takes two consecutive slices and estimates the missing samples of the target slice (T slice) from its left slice (L slice). Compared to the previous methods, slices recovered with the proposed FiCS technique have a maximum correlation with their corresponding original slices. The proposed FiCS technique is evaluated by using both subjective and objective assessment. In subjective assessment, our proposed technique shows less partial volume loss compared to existing techniques. For objective assessment different performance metrics, such as structural similarity index measurement (SSIM), peak signal to noise ratio (PSNR), mean square error (MSE) and correlation, are used and compared with existing interpolation techniques. Simulation results on knee and brain dataset shows that the proposed FiCS technique has improved image quality and performance with even reduced scan time, lower computational complexity and maximum information content.

Highlights

  • Magnetic Resonance Imaging (MRI) is a highly useful medical imaging technique for clinical diagnosis and research because it generates a very detailed picture of an inside body organ, without using any damaging ionizing radiations

  • The subjective method is based on the perceptual assessment of radiologists about the attributes of the reconstructed data sets, while objective methods are based on computational models that can predict perceptual image quality

  • 1D mask is more realistic from the current hardware point of view but 2D is best suitable to represent the original k-space data of multi-slice MRI

Read more

Summary

INTRODUCTION

Magnetic Resonance Imaging (MRI) is a highly useful medical imaging technique for clinical diagnosis and research because it generates a very detailed picture of an inside body organ, without using any damaging ionizing radiations. Deka and Datta [10], Datta et al [45], Datta and Deka [46], [53]–[55] further explored iCS-MRI with different interpolation and reconstruction strategies They reduced the computational cost of their interpolation algorithms [45], [46] but they neither work on reducing the average sampling ratios nor on the consistency of their results. Recent researchers propose iCS with 9% average undersampling ratio [39], [46]

PROPOSED FAST INTERPOLATION SCHEME
SIMULATION AND RESULTS
EVALUATION OF THE PROPOSED FAST INTERPOLATION SCHEME
DISCUSSION AND CONCLUSION