Abstract

Multiphase machines allow enhancing the performance of wind energy conversion systems from the point of view of reliability and efficiency. The enhanced robustness has been traditionally achieved with a mandatory post-fault control reconfiguration. Nevertheless, when the regulation of x-y currents in multiphase drives is done in open-loop mode, the reconfiguration can be avoided. As a consequence, the reliability of the system increases because fault detection errors or delays have no impact on the post-fault performance. This capability has been recently defined as natural fault tolerance. From the point of view of the efficiency, multiphase machines present a better power density than three-phase machines and lower per-phase currents for the same voltage rating. Moreover, the implementation of control strategies based on a variable flux level can further reduce the system losses. Targeting higher reliability and efficiency for multiphase wind energy conversion systems, this work proposes the implementation of an efficient model predictive control using virtual voltage vectors for six-phase induction machines. The use of virtual voltage vectors allows regulation of the x-y currents in open-loop mode and achieving the desired natural fault tolerance. Then, a higher efficiency can be achieved with a simple and universal cost function, which is valid both in pre- and post-fault situations. Experimental results confirm the viability and goodness of the proposal.

Highlights

  • Promoted by new energy policies in different countries, renewable energies currently play an important role in the electricity market [1]

  • Efficiency and robustness are a must in industrial electric drives

  • Even though multiphase machines offer these two features, they are typically achieved at the expense of a high complexity

Read more

Summary

Introduction

Promoted by new energy policies in different countries, renewable energies currently play an important role in the electricity market [1]. Efficiency is a highly appreciated characteristic of WECS because lower losses imply a better exploitation of the wind energy resources and greater torque/power production in post-fault situations. With the aim of providing natural fault tolerance capability and lower losses, an efficient MPC technique based on virtual voltage vectors (EVV-MPC) was suggested in [17]. This work confirmed for the first time the interest of EVV-MPC, improving the efficiency and reliability of six-phase IM drives in pre- and post-fault situations while maintaining the same control scheme. This work goes beyond, providing a detailed analysis and experimental results that confirm the EVV-MPC features in steady or transient states and healthy or post-fault situations and avoiding any sensitivity to parameter detuning when evaluating the optimal magnetic flux level. The obtained conclusions are summarized in the last section

Asymmetrical Six-Phase Induction Drives
Viability of the Proposal
Electric
Pre-fault evaluation proposedVV-MPC
Findings
Conclusions