Abstract
Three simplified prototypes of the first-level trigger front-end device for the muon barrel drift chambers of CMS were tested on a chamber prototype. Tests were performed at several incidence angles of a muon beam and with different magnetic field configurations. The recorded drift times were also used to test a full software model reproducing the actual algorithm applied in the final ASIC being produced. The efficiency performance of this software model and of the tested prototype are presented in this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.