Abstract

The work presents the results of cycle computation for vapor compression pumps based on ozone-safe mixed refrigerants. Non-azeotropic binary refrugerants R32/R152a (30/70) and R32/R134a (30/70) were considere as working substances. Properties of non-azeotropic refrigerants were calculated according to the additivity method of thermodynamic functions and method of Lemmon and Jacobsen. Deviations in the values of thermophysical properties obtained with two methods have been determined. It is shown that at the use of nonazeotropic mixture R32/R152a (30/70), energy conversion ratio increases by 2.2–3.6 % compared with the results for R32/R134a (30/70) at temperature difference between the processes of boiling and condensation from 28 to 53 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.