Abstract

1. In the upper reservoir of the Zagorsk PSS there are standing waves of a complex frequency spectrum having a virtually undamped character. 2. The excess of the level of the crest of the upper reservoir embankment of the PSS should be selected with consideration of not only waves caused by meteorological factors but also the presence of standing waves. 3. The standard systems of measuring the upper pool level of the PSS should provide for averaging the measurements. 4. To eliminate nonproductive water losses through leaks of the close gate apparatus of the PSS units and increased power losses in the SC regime, it is advisable to provide for the installation of preturbine gates at newly planned PSSs.