Abstract

When an explosive detonates or a propellant or flare burns, consumption of the energetic filler should be complete but rarely is, especially in the presence of large amounts of non-combustible materials. Herein we examine three types of perchlorate-containing devices to estimate their potential as sources of contamination in their normal mode of functioning. Road flares, rocket propellants and ammonium nitrate (AN) emulsion explosives are potentially significant anthropogenic sources of perchlorate contamination. This laboratory evaluated perchlorate residue from burning of flares and propellants as well as detonations of ammonium nitrate emulsion explosives. Residual perchlorate in commercial products ranged from 0.094 mg perchlorate per gram material (flares) to 0.012 mg perchlorate per gram material (AN emulsion explosives). The rocket propellant formulations, prepared in this laboratory, generated 0.014 mg of perchlorate residue per gram of material.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.