Abstract

The article presents the results of calculating the efficiency of reconstruction of the gas and air paths of a steam boiler when working on gas and liquid fuel due to the installation of additional gas-air heat exchangers. Due to the utilization of the thermal energy of the flue gases in the newly installed heat exchangers, the air is heated in front of the boiler air heaters and the fuel efficiency is increased by increasing the boiler efficiency. The increase in the efficiency of the "gross" boiler during the operation of the considered TGM-84 boiler on fuel oil with an average annual operating mode was 2.81 %. The flue gas temperature after the boiler air heaters was 178 °C, and the air temperature at the inlet to the air heaters was 99 °C at the average annual load of the boiler, which ensures an almost corrosion-free operation of the air heater packing. It is revealed that when the liquid fuel boilers, installation of new heat exchangers and their strapping on the side of the air and flue gas has a shorter payback period than the boiler gas fired. The simple payback period of the considered technical solution was 6,82 years when working on gas fuel and 1,35 years when working on liquid fuel.