Abstract

Image-guided bronchoscopy techniques have emerged as a means of improving pulmonary nodule biopsy yield. However comparisons of the diagnostic efficacy of electromagnetic navigation bronchoscopy (ENB) and virtual bronchoscopic navigation (VBN) have not reached a consensus. This meta-analysis evaluates the overall diagnostic yield and accuracy of ENB and VBN for pulmonary nodules. A systematic search was conducted to identify relevant articles. Meta-analysis was used to summarize the sensitivities, specificities, and area under the curve for ENB and VBN. Thirty-two studies (1981 patients with pulmonary nodules) were included in this analysis. The pooledsensitivity, specificity, and area under the curve (95% confidence interval) of ENB were 0.80 (0.73-0.85), 0.81 (0.71-0.88), and 0.87 (0.84-0.90), respectively. Corresponding VBN values were 0.80 (0.76-0.83), 0.65 (0.56-0.73), and 0.81 (0.78-0.85), respectively. Comparison of the 2 techniques revealed that ENB had higher specificity and area under the curve but no difference in sensitivity. Both ENB and VBN are valuable tools in the diagnosis of lung nodules. ENB achieved a higher specificity than VBN in the diagnose of lung nodules, whereas ENB performed better than VBN for pulmonary nodules. These results are due to the real-time positioning function of ENB.