Abstract

The objective of this research was to understand the influence of oxygenation at two different oxygen flow rates (0.105 and 0.210 L/L/h) on autothermal thermophilic aerobic digestion (ATAD), and on the overall performance of Dual Digestion (DD). Profile experiments on an ATAD reactor showed that a significant portion of volatile fatty acids and ammonia were produced in the first 12 h period, and both followed first order kinetics. Ammonia concentrations of ATAD effluent were 1015 mg/L and 1450 mg/L, respectively, at the two oxygenation rates. Ammonia production was not complete in the ATAD reactor at the lower oxygenation rate. However, it was sufficient to maximize volatile solids reduction in the DD process. The biological heat of oxidations were 14,300 J/g Volatile Solids (VS) removed and 15,900 J/g VS removed for the two oxygen flow rates, respectively. The ATAD step provided enhanced digestion for the DD process with higher volatile solids removal and methane yield when compared to conventional digestion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.