Abstract

The weighted average concentration (WAC) of total suspended solids (TSS) in stormwater effluent from a continuous deflective separation (CDS) unit in Port Jackson (Australia) catchment was reduced by an average 28% during six high-flow events, but some TSS was released during turbulent, high-flow events. The average removal efficiency of metals Cr, Cu, Pb Mn, Ni, Zn and Fe varied considerably (−49% for Pb and +10% for Mn), whereas Ni and Zn were inefficiently removed by the device. Average concentrations of TKN, NOx and TP were similar at both in- and out-flow points and faecal coliforms counts were slightly reduced.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.