Abstract

We report injection efficiency measurements when an external primary low charge ion beam is injected into Dioné EBIS. These measurements have been performed using nitrogen and argon ion beams. The total efficiencies reach 59 and 52% respectively. The partial efficiencies, related to the main ionic charge state, reaches 30% for N 7+ and 9.4% for Ar 14+. These results correspond to an injection before the confinement period (fast injection mode). The other method (injection during the confinement time) has been also performed using nitrogen ions. The results are less spectacular: only a 0.4% total efficiency has been measured.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.