Abstract

Efficient liquefaction of hydrogen is a crucial part for the large-scale storage and long-distance transportation of hydrogen. Helium Brayton cycle based on high-speed turbo-expanders has been widely employed in small and medium hydrogen liquefiers. In present study, a coupled model is proposed to predict the performance and cooling-down process of helium turbo-expanders with brake blower, and validation experiments were performed on a helium turbo-expander of a 2 t/d hydrogen liquefier. Experimental results indicated that the characteristic ratio of expander varied significantly during the cooling-down process which led to a large deviation from the optimal efficiency. The impact of brake pressure on the characteristic ratio and efficiency of the helium turbo-expander is studied, and a variable pressure control method is proposed for the efficient operation of turbo-expanders during the cooling-down process of a hydrogen liquefier. Compared with the constant brake pressure control method, the variable pressure control method can increase the expander efficiency by 5%–10% during the cooling-down process in the high temperature zone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.