Abstract

BackgroundPathway-targeted or low-density arrays are used more and more frequently in biomedical research, particularly those arrays that are based on quantitative real-time PCR. Typical QPCR arrays contain 96-1024 primer pairs or probes, and they bring with it the promise of being able to reliably measure differences in target levels without the need to establish absolute standard curves for each and every target. To achieve reliable quantification all primer pairs or array probes must perform with the same efficiency.ResultsOur results indicate that QPCR primer-pairs differ significantly both in reliability and efficiency. They can only be used in an array format if the raw data (so called CT values for real-time QPCR) are transformed to take these differences into account. We developed a novel method to obtain efficiency-adjusted CT values. We introduce transformed confidence intervals as a novel measure to identify unreliable primers. We introduce a robust clustering algorithm to combine efficiencies of groups of probes, and our results indicate that using n < 10 cluster-based mean efficiencies is comparable to using individually determined efficiency adjustments for each primer pair (N = 96-1024).ConclusionsCareful estimation of primer efficiency is necessary to avoid significant measurement inaccuracies. Transformed confidence intervals are a novel method to assess and interprete the reliability of an efficiency estimate in a high throughput format. Efficiency clustering as developed here serves as a compromise between the imprecision in assuming uniform efficiency, and the computational complexity and danger of over-fitting when using individually determined efficiencies.

Highlights

  • Pathway-targeted or low-density arrays are used more and more frequently in biomedical research, those arrays that are based on quantitative real-time PCR

  • Estimating Efficiency with Confidence We developed a novel algorithm for the adjustment of primer and probe efficiencies, as it relates to low density real-time quantitative polymerase chain reaction (QPCR) arrays

  • As array-based measurements for DNA, mRNA and microRNA levels migrate into the mainstay of molecular biology, failure to carefully consider the efficiency of each individual reaction or assay can lead to significant measurement inaccuracies

Read more

Summary

Introduction

Pathway-targeted or low-density arrays are used more and more frequently in biomedical research, those arrays that are based on quantitative real-time PCR. Lower-density or targeted arrays have been introduced These comprise on the order of 10-1000 targets and represent an intermediate between 1 target assays, e.g. the viral load assay for HIV, and genomewide microarrays, comprising 10,000 1,000,000 targets, e.g. AffymetrixTM arrays. They can be treated as either a collection of individual assays or as microarrays. On the one hand high density microarray-based analysis methods do not capture all the information that is available. This results in lower than possible linear range and lower discriminating power.

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.