Abstract
This paper describes a method of calibrating the efficiency of an on-line detection device for fuel rod failure in a pressurized water reactor. 214Am, 137Cs, 60Co and 24Na were selected to produce 4 sets of liquid calibration sources, and a calibration system that could simulate the on-site measurement of the on-line detection device was established. Efficiency calibration was performed against γ-ray lines, which could be identified by a LaBr3(Ce) detector. After a true coincidence summing correction, an efficiency curve of the on-line detection device for fuel rod failure was obtained, with a calibration uncertainty of 3.5%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.