Abstract

IntroductionRetrieving a separated file in the root canal system requires a skilled clinician. A metal file can be removed by ablation via the neodymium:yttrium-aluminum-perovskite (Nd:YAP) laser; however, the efficiency and potential hazards of the ablation procedure are still unclear. The aim of this study was 2-fold: to investigate the efficiency of file ablation using the Nd:YAP laser and to evaluate the rise in temperature of the root surface in vitro. MethodsIn part 1 of this study, #10 and #15 C-files (VDW GmbH, Munich, Germany) and ProTaper Next X1 and X2 files (Dentsply Maillefer, Ballaigues, Switzerland) were selected. Under 8.5×, the Nd:YAP laser was used to ablate the files starting at the tip of the file. The length of the file was recorded after each 5-pulse ablation. In part 2 of this study, 3 files each of the #15 C-file and the ProTaper Next X2 were separated in 6 distal roots of mandibular second molars with single canals. Two-pulse and 5-pulse modes were used to ablate the separated files, and the rise in root surface temperature was recorded with an infrared camera. Another 3 unaltered distal roots served as the negative control. For scanning electron microscopic evaluation, the teeth were split with bone scissors and observed under a scanning electron microscope to evaluate the surface change of the file and the root canal wall. ResultsThe average length of the ablated files after each 5-pulse interval was 0.113–0.158 mm with no statistical difference between the different files.The temperature rise of the negative control group (mean ± standard deviation = 1.86° ± 0.11°C and 5.81° ± 0.35°C for the 2- and 5-pulse group) was significantly lower than the roots with separated files (mean ± standard deviation = 3.74° ± 0.20°C and 4.02° ± 0.11°C for 2-pulse C-file and ProTaper Next X2; 8.47° ± 0.19°C and 9.04° ± 0.20°C for 5-pulse C-file and ProTaper Next X2). The temperature rise of all groups was lower than 10°C. The 2-pulse group showed a lower temperature rise than the 5-pulse group. The diameter or the type of alloy had no effect on the temperature rise. ConclusionsSeparated files (stainless steel or nickel-titanium alloy) can be ablated by the Nd:YAP laser. When the number of pulses is less than 5, the temperature rise of the root surface is considered safe to the surrounding periodontium.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call