Abstract
BackgroundArtificial urinary sphincter (AUS) is a gold standard treatment in male stress urinary incontinence but remains poorly used in elderly patients. ObjectiveTo assess the efficacy, safety, and reoperation-free survival of AUS implantation in male patients over 75 yr of age. Design, setting, and participantsWe retrospectively reviewed the charts of all 1233 non-neurological male AUS implantations between 2005 and 2020 at 13 French centers. We compared 330 patients ≥75 yr old (GROUP75+) with 903 patients <75 yr old (GROUP75–) at the time of AUS implantation. Outcome measurements and statistical analysisOur primary endpoint was social continence at 3 mo defined as the use of one or fewer pad daily. We used Kaplan-Meier analyses to assess reoperation-free survival. We sought factors of erosion using logistic regression. Results and limitationsEarly postoperative continence was comparable in both groups (74.4% vs 80.1%, p = 0.114). We observed a higher rate of postoperative complications in GROUP75+ (18.8% vs 12.6%, p = 0.014), but the complications were more frequently of low grade in GROUP75+ (p = 0.025). The overall reoperation-free survival was similar (p = 0.076) after a median follow-up of 2 yr. However, patients in GROUP75+ had poorer explantation-free survival (p < 0.0001). A history of radiotherapy was a predictive factor of erosion (odds ratio [OR] = 5.31, p < 0.01), but age was not (OR = 1.08, p = 0.87). Unfortunately, our dataset did not include a systematic geriatric evaluation. ConclusionsAUS in elderly patients appears to be an effective option to treat stress urinary incontinence. However, we observed more postoperative complications and explantations, although age was not associated with the onset of erosion. A prospective study is required to determine whether a geriatric evaluation would be an effective strategy to select patients before surgery. Patient summaryIn this study, we looked at outcomes of artificial urinary sphincter in elderly men in a large population. We found satisfying efficacy but slightly more postoperative complications and device infections.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.