Abstract
This study aimed to assess the efficacy of hp-guar eye drops on tear film index and ocular surface dynamics under desiccating conditions using protection and relief treatment modalities. The 12 normal, non-dry eye participants were subjected to adverse environmental conditions using a Controlled Environment Chamber (CEC) where the relative humidity (RH) was 5% and the ambient temperature was 21°C. The participants were screened for ocular symptoms, tear osmolarity, ocular surface temperature (OST), tear production using the Ocular Surface Disease Index questionnaire (OSDI), OcuSense TearLab Osmometer, FLIR System ThermaCAM P620, and Schirmer strips. Tear production was calculated by the Tear Function Index test (TFI). The mean tear film osmolarity decreased significantly from 296mOsm/L at 40% RH to 285mOsm/L at 5% RH (p = 0.01). Conflicting responses were seen for osmolarity in protection and relief. Mean tear osmolarity was significantly higher in the protection method in comparison to the relief method (p = 0.005). The mean TFI increased from 557 at 40% to 854 at 5% (p = 0.02). A significant increase in TFI was observed in the relief method in comparison with both 40% (p = 0.001) and 5% (p = 0.04). In the relief method, the mean TFI score went up to 1139 when hp-guar was installed. A significant improvement in ocular comfort was experienced in both the protection (p = 0.041) and relief (p = 0.010) methods at 5% RH. The instillation of hp-guar drops in the relief method resulted in a significant reduction in OST. The mean OST dropped to 33.01 ºC, significantly lower than the recorded OST for both normal (p = 0.040) and dry (p = 0.014) environmental conditions. Hp-guar drops significantly improve tear film parameters under a desiccating environment, however, tear film parameters respond differently to the management modalities. In the protection method, tear film osmolarity was protected against a dry environment, while in the relief mode, an improvement in tear production and a decrease in ocular surface temperature were seen. Hp-guar performance could be maximized for the management of exposure to adverse environments by using a treatment protocol that targets the most affected parameters in each group of patients. Using CEC has the potential to provide researchers with a readily available method to evaluate the efficiency of tear supplementation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.