Abstract

Editor—Airway exchange catheters (AECs) are commonly used in difficult airways management as a guide for re-intubation or ventilation when attached to a jet ventilator.1Popat M Mitchell V Dravid R Patel A Swampillai C Higgs A Difficult Airway Society Guidelines for the management of tracheal extubation.Anaesthesia. 2012; 67: 318-340Crossref PubMed Scopus (6) Google Scholar However, barotrauma resulting in pneumothorax has been a major concern when using jet ventilation with AECs.2Cooper RM Cohen DR The use of an endotracheal ventilation catheter for jet ventilation during a difficult intubation.Can J Anaesth. 1994; 41: 1196-1199Crossref PubMed Scopus (32) Google Scholar, 3O’Sullivan TJ Healy GB Complications of venturi jet ventilation during microlaryngeal surgery.Arch Otolaryngol. 1985; 111: 127-131Crossref PubMed Scopus (50) Google Scholar, 4Duggan LV Law JA Murphy MF Brief review: supplementing oxygen through an airway exchange catheter: efficacy, complications, and recommendations.Can J Anaesth. 2011; 58: 560-568Crossref PubMed Scopus (59) Google Scholar The cause of these complications is often the excessive driving pressure with jet ventilation (15–50 psi) or airway obstruction.3O’Sullivan TJ Healy GB Complications of venturi jet ventilation during microlaryngeal surgery.Arch Otolaryngol. 1985; 111: 127-131Crossref PubMed Scopus (50) Google Scholar Therefore, it has been suggested that minimizing intratracheal pressure and prolonging expiratory times can reduce the risk of barotrauma.4Duggan LV Law JA Murphy MF Brief review: supplementing oxygen through an airway exchange catheter: efficacy, complications, and recommendations.Can J Anaesth. 2011; 58: 560-568Crossref PubMed Scopus (59) Google Scholar We propose an alternative method of ventilation via an AEC with a customized cuff (Fig. 1). A cuffed AEC was created by placing a 5 cm long latex cuff over the distal side ports of a 14 and 19 Fr AEC (Cook Critical Care, Bloomington, IN, USA) and inserting a 1 cm long internal resistor (14 G i.v. catheter for 14 Fr AEC or 11 Fr Cook AEC for 19 Fr AEC) into the distal tip of each AEC (Fig. 1). Briefly, because the lumen of the cuff freely communicated through the side ports with the lumen of the AEC, the cuff inflated during inspiration due to pressure generated by the resistor and during exhalation, the cuff deflated allowing expiratory flow around the AEC (Fig. 1). We evaluate the efficacy of ventilation through novel cuffed AECs using a tracheal/lung model study. The lung model (Dual adult TTL training/test lung, Model 1600, Michigan Instruments Inc., MI, USA) was connected to the distal end of a tracheal model (Airway demonstration model, Laerdal, Stavanger, Norway). The lung model was adjusted to simulate normal lung mechanics (compliance 50 ml cm H2O−1, resistance 5 cm H2O litre−1 s−1). The proximal end was connected to an intensive care unit (ICU) ventilator (Puritan Bennett™ 840, Covidien, Boulder, CO, USA) set to pressure control with peak pressure 40 or 70 cm H2O. Ventilation was performed at a respiratory rate of 10 bpm with inspiratory:expiratory (I:E) ratios of 1:2, and 1:1. The distal tip of the AEC was placed 3 cm above the carina of the tracheal model. A flow/pressure sensor (NICO Cardiopulmonary Management System, Model 7300, Respironics Corp., Murrysville, PA, USA) was placed between the distal end of the tracheal model and the model lung. With the cuffed AEC, ICU ventilator was able to generate reasonable tidal volume [493 (151) ml with 19 Fr, range: 328–694 ml and 293 (103) ml with 14 Fr, range: 180–429 ml]. The mean peak inspiratory airway pressure was 11.5 (2.8) cm H2O with 19 Fr (range: 8.4–15.3 cm H2O) and 7.5 (2.2) cm H2O with 14 Fr (range: 5.0–10.4 cm H2O). Our results indicate that cuffed AEC may enable practitioners to use ordinary ICU ventilator and achieve reasonable tidal volume and provide at least partial ventilatory support at much lower driving pressure than with the jet ventilation. The ability to ventilate patients using lower pressure settings may reduce the risk of barotraumas. Because the high resistance generated by the small inner diameter of the AEC, peak inspiratory airway pressure was within a lung protective range. In addition, ICU ventilators are much more commonly available than jet ventilators. Because this study was not conducted on patients, results from our study should be cautiously extrapolated to actual patient care until clinical studies can be conducted. R.M.K. is a consultant for Covidien, has received research grants from Covidien and Hollester, and has received honorarium for lecturing from Maquet.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call